EN  |  FR
Download our Catalogue Search our Catalogue of Motors Contact Us Contact Us
Note: Image shown is a representation of the product and may not represent the exact model.

NEMA Motors FDA.334C-Y-RND

0.33 HP, 1800 RPM, 1 Phase, 115/208-230V, 56Y Round Body/Y-Flange, TEFC

Login for pricing & stock information


Quick Specs

  • HP 0.33
  • RPM 1800
  • PHASE 1
  • VOLTAGE 115/208-230V
  • MOUNTING Round Body/Y-Flange
  • ENCLOSURE TEFC

Product Overview

Single phase, enhanced performance cold rolled steel, dual capacitor energy-saving, high torque design.

4 pole, 1/3 to 1.5HP, specifically designed for use with farm feeding auger drives where high starting torque and low current draw is required.


Motor Features

STANDARD FEATURES
  • Klixon manual reset thermal overload protectors (FDR models only)
  • Over 300% starting torque
  • 1.15 Service Factor
  • 18 Month warranty
  • High quality Japanese switches with beryllium coated contacts
  • Cold rolled steel construction with cast iron end bells and c-flange kits
  • Rubber sealed bearings
  • 1045 Steel shaft
  • Surface finish:
    • Alkyd enamel RAL7024 - Graphite Gray
    • Black oxide surface treatment for increased corrosion resistance
  • Stainless steel nameplate
  • Corrosion resistant hardware
OPERATING PARAMETERS
  • Continuous (S1) duty
  • Ambient temperatures up to 40ºC
  • Installation up to 1000 MASL (3300 ft.)

INGRESS PROTECTION

The standard degree of enclosure protection is IP54 (Weather Proof). Both drive end and non-drive end are fitted with v-seals. Motors include high quality molded capacitor cover gaskets. Conduit box lid and body are sealed with fitted rubber gaskets. DE/NDE end bell fitted with sintered brass one-way drain.


INSULATION RATING
  • Class F Insulation
  • Vacuum Impregnated
  • Designed to Class B temperature rise


Specifications

Download Specifications
ELECTRICAL DATA
Rated Motor Output Power
0.33
HP
-
kW
Rated Motor Speed
1725
r/min 60Hz
-
r/min 50Hz
Rated Motor Voltage (+/-10%)
115/208-230
V/60Hz
-
V/50Hz
Rated Motor Current
3.7/2.0-1.85
A (In) @ 60Hz
-
A (In) @ 50Hz
Phase
1
Ø
Locked Rotor Current
12.6779
xFLA (Il/In)
Fl Current @ 208V
2
A (In) @ 60Hz
Service Factor
1.15
@ 60Hz
-
@ 50Hz
KVA Code
N
60Hz
-
50Hz
Nominal Efficiency
67
% @ 60Hz
Nominal Power Factor
0.9
cosφ @ 60Hz
Leads (Qty, Size)
7
Connection
-
Coil Resistance
-
Ω
Start Capacitor
150/165
μF/V
Run Capacitor
30/250
μF/V
VFD DUTY (S.F. 1.0)
RATIO
Hz
Variable Torque
30
250
Constant Torque
150
165
FULL LOAD TEMPERATURE RISE
Full Load Temperature Rise
25.1
ºC @ 60Hz
-
ºC @ 50Hz
GENERAL DATA
Frame Size
56Y
Enclosure
TEFC
Mounting
Round Body/Y-Flange
Approximate Weight (lbs.)
-
Casing Material / Fan Cover
Rolled Steel
Steel
Shaft Material
1045
NEMA Design
L
Degree of Protection (IP)
54
Insulation Class / Temp Rise (60Hz)
F
B
Tropicalization
NO
Duty
Cont. / S1
Conduit Box Location
0.88"
Feet Removable / Double Drilled
NO
NO
Paintwork
7024
Graphite Gray
MECHANICAL DATA
Bearing DE Side
6203-2RS
Bearing ODE Side
6203-2RS
Grease Type
Mobil Polyrex EM
Compensation Ring (wavy washer)
NDE
Moment of Inertia (lb-ft2)
-
Sound Pressure @ 3 FT dBA
-
SITE CONDITIONS
Ambient Temperature (℃)
40
Meters Above Sea Level (MASL)
1000
HAZARDOUS LOCATIONS
CSA Certified
-
Temperature Code
-
-

Nameplate

Download Nameplate
NAMEPLATE DATA
60Hz
50Hz
Horse Power
0.33
-
RPM
1725
-
Voltage
115/208-230
-
Full Load Amps
3.7/2.0-1.85
-
Service Factor
1.15
-
KVA Code
N
-
Full Load Amps (208V)
2
-
Nominal Efficiency
67
-
Nominal Power Factor
0.9
-
Design
L
Frame
56Y
Enclosure Type
TEFC
IP Rating
54
Duty
Cont. / S1
Insulation Class
F
Ambient Rating
40
Drive End Bearing
6203-2RS
Opposite Drive End Bearing
6203-2RS
Weight (lbs)
-
NAMEPLATE LAYOUT

Your browser does not support SVG!



CAPACITOR DATA
μF
VOLTAGE
Start Capacitor
150
165
Run Capacitor
30
250
*For max speed please contact Techtop Canada
HAZARDOUS LOCATIONS
-
Class / Division
-
-
Groups
-

Performance

Download Performance Data
PERFORMANCE LOAD VALUES, HIGH VOLTAGE, 60Hz
TYPICAL PERFORMANCE - NOT GUARANTEED VALUES
TORQUE VALUES
TORQUE (lb-ft)
TORQUE (% FULL LOAD)
PERFORMANCE VALUES
Locked Rotor Torque
3.697408
368
Start Configuration
DOL
Pull-Up Torque
2.431447652
242
Starting Current (A)
12.6779
Breakdown Torque
2.933812869
292
No-Load Current (A)
0.668
Full Load Torque
1.004730434
100
No-Load Power Factor
-


% OF RATED LOAD
25
50
75
100
125
S.F.
Line Amperes (A)
-
-
-
1.571
-
-
Efficiency (%)
-
-
-
71.9
-
-
Speed (r/min)
-
-
-
1760.3
-
-
Power Factor (cosφ)
-
-
-
0.963
-
-
Input Power(kW)
-
-
-
0.347
-
-

Drawings & Wiring

3D CAD DRAWING 2D CAD DRAWING
Download PDF Drawing
DRAWING NUMBER
DIMENSIONS
MOUNTING
CASING MATERIAL
RD1-RS-TF-56Y-RND
Inches
Round Body/Y-Flange
Rolled Steel





Download Wiring Diagram
DRAWING NUMBER
CONNECTION
NUMBER OF LEADS
THERMAL PROTECTION
NEMA-FD-56-140T
-
7
Manual Reset

Parts & Accessories

There are currently no parts or accessories available for this model.